Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (143)Preflabel
CDSEICP2Concentration standard error of cadmium {Cd CAS 7440-43-9} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CDVOLDMSConcentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CDVOLDMTConcentration standard deviation of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CDXXICD2Concentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CDZNICP1Concentration of zinc {Zn CAS 7440-66-6} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification, chelation, solvent extraction and inductively-coupled plasma mass spectrometry
CEKG07MSConcentration standard deviation of cerium {Ce CAS 7440-45-1} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CEKG45MSConcentration of cerium {Ce CAS 7440-45-1} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CGA87039Concentration of gallium {Ga CAS 7440-55-3} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CLA87033Concentration of lanthanum {La CAS 7439-91-0} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
COICPMS2Concentration of cobalt {Co CAS 7440-48-4} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
COICPMSDConcentration standard deviation of cobalt {Co CAS 7440-48-4} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CR3SD001Concentration standard deviation of chromium, trivalent {Cr3+ CAS 16065-83-1} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, precipitation, acidification and inductively-coupled plasma mass spectrometry
CR3XX001Concentration of chromium, trivalent {Cr3+ CAS 16065-83-1} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, precipitation, acidification and inductively-coupled plasma mass spectrometry
CRXSD001Concentration standard deviation of chromium {Cr CAS 7440-47-3} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CRXXX001Concentration of chromium {Cr CAS 7440-47-3} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CTI87035Concentration of titanium {Ti CAS 7440-32-6} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CUICPMS2Concentration of copper {Cu CAS 7440-50-8} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CUSDKGI5Concentration standard deviation of copper {Cu CAS 7440-50-8} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CUVOLDMSConcentration of copper {Cu CAS 7440-50-8} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CUVOLDMTConcentration standard deviation of copper {Cu CAS 7440-50-8} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CUXXICD2Concentration of copper {Cu CAS 7440-50-8} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CVA11041Concentration of vanadium {V CAS 7440-62-2} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acid digestion and inductively-coupled plasma mass spectrometry
CYT87031Concentration of yttrium {Y CAS 7440-65-5} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
DGTLALSDConcentration standard deviation of aluminium {Al CAS 7429-90-5} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLALXXConcentration of aluminium {Al CAS 7429-90-5} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry