Conceptid (1130) | Preflabel |
---|
DMSSGCTX | Concentration of dimethyl seleno sulphide per unit volume of the water body [dissolved plus reactive particulate phase] by purging, cryogenic trapping and gas chromatography-mass spectrometry |
DMSTGCTX | Concentration of dimethyl sulfide+dimethylsulfoniopropionate {DMS+DMSP dimethyl sulphide+dimethylsulphoniopropionate} per unit volume of the water body [dissolved plus reactive particulate phase] by gas chromatography |
DMSXGCDX | Concentration of dimethyl sulfide {DMS CAS 75-18-3} per unit volume of the water body [dissolved plus reactive particulate phase] by purging, cryogenic trapping and gas chromatography |
DN2OGCSD | Concentration standard deviation of nitrous oxide {N2O CAS 10024-97-2} per unit volume of the water body [dissolved plus reactive particulate phase] by gas chromatography |
DN2OGCTX | Concentration of nitrous oxide {N2O CAS 10024-97-2} per unit volume of the water body [dissolved plus reactive particulate phase] by gas chromatography |
DN2OXX01 | Concentration of nitrous oxide {N2O CAS 10024-97-2} per unit volume of the water body [dissolved plus reactive particulate phase] |
DOSDPR01 | Concentration standard deviation of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ Beckmann probe |
DOXYAAOP | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by optode |
DOXYCZ01 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor and calibration against sample data |
DOXYMMOP | Concentration recalculated to zero salinity of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] |
DOXYOP01 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ oxygen optode |
DOXYPE01 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ pulsed electrode |
DOXYPR01 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ Beckmann probe |
DOXYPR02 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ Beckmann probe (second sensor) |
DOXYSC01 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and calibration against sample data |
DOXYSC02 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor (second sensor) and calibration against sample data |
DOXYSD01 | Concentration standard deviation of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and calibration against sample data |
DOXYSE01 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by YSI in-situ oxygen and temperature probe |
DOXYSE02 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by YSI profiling oxygen and temperature probe |
DOXYSU01 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and no calibration against sample data |
DOXYSU02 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor (second sensor) and no calibration against sample data |
DOXYUZ01 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor and no calibration against sample data |
DOXYUZ02 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor (second sensor) and no calibration against sample data |
DOXYWITX | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Winkler titration |
DOXYZZ01 | Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor |