Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (19)Preflabel
CTM01616Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry
CTM01717Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry
CTM02121Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry
CTM02222Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry
CTM02626Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry
CTM02727Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry
LGCUCSV5Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry
LGCUSDA5Concentration standard deviation of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry
LOGCUCS5Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry
LTM01818Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry
LTM01919Log ligand binding strength lower uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry
LTM02020Log ligand binding strength upper uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry
LTM02323Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry
LTM02424Log ligand binding strength lower uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry
LTM02525Log ligand binding strength upper uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry
LTM02828Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry
LTM02929Log ligand binding strength lower uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry
LTM03030Log ligand binding strength upper uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry
SDLOGCU7Log ligand binding strength standard deviation of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry