Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (12)Preflabel
CDXXICD2Concentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
CUXXICD2Concentration of copper {Cu CAS 7440-50-8} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
FEXXICD2Concentration of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
MNXXICD2Concentration of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
NIXXICD2Concentration of nickel {Ni CAS 7440-02-0} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
PBXXICD2Concentration of lead {Pb CAS 7439-92-1} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
SDCDICP2Concentration standard deviation of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
SDCUICP2Concentration standard deviation of copper {Cu CAS 7440-50-8} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
SDFEICP2Concentration standard deviation of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
SDMNICP2Concentration standard deviation of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
ZN04ICP6Concentration of zinc {Zn CAS 7440-66-6} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
ZNSDICP6Concentration standard deviation of zinc {Zn CAS 7440-66-6} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry