Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (50)Preflabel
DOXYUCKGConcentration of oxygen {O2 CAS 7782-44-7} per unit mass of the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and no calibration against sample data
DOXYUZ01Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor and no calibration against sample data
DOXYUZ02Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor (second sensor) and no calibration against sample data
DOXYWITXConcentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Winkler titration
DOXYZZ01Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor
DOXYZZXXConcentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase]
OXSDSU01Concentration standard deviation of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and no calibration against sample data
OXSDSU02Concentration standard deviation of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor (second sensor) and no calibration against sample data
OXYSBB01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by in-situ Beckmann probe and computation from concentration using Benson and Krause algorithm
OXYSBB02Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by in-situ Beckmann probe (second sensor) and computation from concentration using Benson and Krause algorithm
OXYSBE01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by in-situ pulsed electrode and computation from concentration using Benson and Krause algorithm
OXYSBW01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by Winkler titration and computation from concentration using Benson and Krause algorithm
OXYSMOD1Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by model prediction
OXYSOP01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by in-situ oxygen optode and computation from concentration
OXYSSC01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and calibration against sample data and computation from concentration using Benson and Krause algorithm
OXYSSE01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by YSI in-situ oxygen and temperature probe and computation from concentration
OXYSSU01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and computation from concentration using Benson and Krause algorithm
OXYSWB01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by in-situ Beckmann probe and computation from concentration using Weiss algorithm
OXYSWE01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by in-situ pulsed electrode and computation from concentration using Weiss algorithm
OXYSWW01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by Winkler titration and computation from concentration using Weiss algorithm
OXYSZW01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by Winkler titration and computation from concentration
OXYSZZ01Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase]
OXYSZZ02Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by second sensor
PCODGFF1Chemical oxygen demand {particulate COD} per unit volume of the water body [particulate >GF/F phase]
PO2XXXXXPartial pressure of oxygen {O2 CAS 7782-44-7} in the water body