Conceptid (12) | Preflabel |
---|
LG4ECSL1 | Concentration of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
LG4ECSL2 | Concentration of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
LG4ECSL3 | Concentration of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
LG4ESDL1 | Concentration standard deviation of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
LG4ESDL2 | Concentration standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
LG4ESDL3 | Concentration standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
LOG4ECL1 | Log ligand binding strength of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
LOG4ECL2 | Log ligand binding strength of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
LOG4ECL3 | Log ligand binding strength of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
LOG4SDL1 | Log ligand binding strength standard deviation of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
SDLO4EL2 | Log ligand binding strength standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |
SDLO4EL3 | Log ligand binding strength standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry |