Conceptid (399) | Preflabel |
---|
CD112SEM | Enrichment with respect to 112Cd/110Cd in NIST SRM 3108 standard error of cadmium-112 {112Cd CAS 14336-65-3} {epsilon(112/110)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry |
CD112SRM | Enrichment with respect to 112Cd/110Cd in NIST SRM 3108 of cadmium-112 {112Cd CAS 14336-65-3} {epsilon(112/110)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry |
CDEFFICP | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 of cadmium-114 {114Cd CAS 14041-58-8} {epsilon(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry |
CDENRICP | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 of cadmium-114 {114Cd CAS 14041-58-8} {epsilon(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry |
CDENRICQ | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 uncertainty of cadmium-114 {114Cd CAS 14041-58-8} {epsilon(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry |
CDESDICP | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 standard deviation of cadmium-114 {114Cd CAS 14041-58-8} {epsilon(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry |
CDESEICP | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 standard error of cadmium-114 {114Cd CAS 14041-58-8} {epsilon(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry |
COLGCVZZ | Log ligand binding strength of cobalt-complexing organic ligands {Co_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
DTA87001 | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 standard error of cadmium-114 {114Cd CAS 14041-58-8} {delta(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry and using the delta notation |
DTEFFICP | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 of cadmium-114 {114Cd CAS 14041-58-8} {delta(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry and using the delta notation |
DTENRICP | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 of cadmium-114 {114Cd CAS 14041-58-8} {delta(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry and using the delta notation |
DTENRICQ | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 uncertainty of cadmium-114 {114Cd CAS 14041-58-8} {delta(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry and using the delta notation |
DTESDICP | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 standard deviation of cadmium-114 {114Cd CAS 14041-58-8} {delta(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry and using the delta notation |
ECA87001 | Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 standard error of cadmium-114 {114Cd CAS 14041-58-8} {epsilon(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry |
ED30SBSI | Enrichment standard deviation of silicon-30 in biogenic silica {30Si_in_BSi} {delta(30)Si} in the water body [particulate >0.4/0.45um phase] by filtration and inductively-coupled plasma mass spectrometry |
ED30SSLC | Enrichment standard deviation of silicon-30 in silicate {30Si_in_SiO44-} {delta(30)Si} in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and inductively-coupled plasma mass spectrometry |
EFE56P01 | Enrichment with respect to 56Fe/54Fe in IRMM-14 of iron-56 {56Fe CAS 14093-02-8} {delta(56)Fe} in the water body [particulate >0.4/0.45um phase] by filtration and inductively-coupled plasma mass spectrometry |
EFE56SD1 | Enrichment with respect to 56Fe/54Fe in IRMM-14 standard deviation of iron-56 {56Fe CAS 14093-02-8} {delta(56)Fe} in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and inductively-coupled plasma mass spectrometry |
EFE56SD2 | Enrichment with respect to 56Fe/54Fe in IRMM-14 standard deviation of iron-56 {56Fe CAS 14093-02-8} {delta(56)Fe} in the water body [particulate >0.4/0.45um phase] by filtration and inductively-coupled plasma mass spectrometry |
EFE56W01 | Enrichment with respect to 56Fe/54Fe in IRMM-14 of iron-56 {56Fe CAS 14093-02-8} {delta(56)Fe} in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and inductively-coupled plasma mass spectrometry |
EIR87001 | Enrichment with respect to 56Fe/54Fe in IRMM-14 of iron-56 {56Fe CAS 14093-02-8} {delta(56)Fe} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry |
EIR87002 | Enrichment with respect to 56Fe/54Fe in IRMM-14 standard deviation of iron-56 {56Fe CAS 14093-02-8} {delta(56)Fe} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry |
EIR87003 | Enrichment with respect to 56Fe/54Fe in IRMM-14 combined uncertainty of iron-56 {56Fe CAS 14093-02-8} {delta(56)Fe} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and inductively-coupled plasma mass spectrometry |
EN30SBSI | Enrichment of silicon-30 in biogenic silica {30Si_in_BSi} {delta(30)Si} in the water body [particulate >0.4/0.45um phase] by filtration and inductively-coupled plasma mass spectrometry |