Conceptid (95) | Preflabel |
---|
ESSSZZ01 | Speed standard deviation of wind {wind speed} in the atmosphere |
ESZSSS01 | Upward velocity standard deviation of airflow in the atmosphere by in-situ anemometer |
ESZSZZ01 | Upward velocity standard deviation of airflow in the atmosphere |
EWDRSD01 | Direction (from) standard deviation of wind relative to True North {wind direction} in the atmosphere by in-situ anemometer |
EWDRSD02 | Direction (from) standard deviation of wind relative to True North {wind direction} in the atmosphere by in-situ anemometer (second sensor) |
EWSBSD02 | Speed standard deviation of wind {wind speed} in the atmosphere by in-situ anemometer (second sensor) |
FCSDECAL | Fugacity standard deviation of carbon dioxide {CO2 CAS 124-38-9} {fCO2} in the experiment water sample by computation |
FCSDWCAL | Fugacity standard deviation of carbon dioxide {CO2 CAS 124-38-9} {fCO2} in the water body by computation |
FE56SDPW | Enrichment standard deviation of total iron-56 {total_56Fe CAS 14093-02-8} {delta(56)Fe} in the sediment pore water [dissolved plus reactive particulate <0.2um phase] by anion exchange chromatography and inductively-coupled plasma mass spectrometry |
FE57SDPW | Enrichment standard deviation of total iron-57 {total_57Fe} {delta(57)Fe} in the sediment pore water [dissolved plus reactive particulate <0.2um phase] by anion exchange chromatography and inductively-coupled plasma mass spectrometry |
IRRDPPSD | Downwelling 2-pi scalar irradiance as photons standard deviation of electromagnetic radiation (PAR wavelengths) in the water body by 2-pi scalar radiometer |
IRRDSD01 | Downwelling vector irradiance as photons standard deviation of electromagnetic radiation (PAR wavelengths) in the water body by cosine-collector radiometer |
IRRDSV11 | Downwelling vector irradiance as photons standard deviation of electromagnetic radiation (PAR wavelengths) in the atmosphere by cosine-collector radiometer |
IRRUPPSD | Upwelling 2-pi scalar irradiance as photons standard deviation of electromagnetic radiation (PAR wavelengths) in the water body by 2-pi scalar radiometer |
IRRUUVSD | Upwelling vector irradiance as photons standard deviation of electromagnetic radiation (PAR wavelengths) in the water body by cosine-collector radiometer |
LWRDSD01 | Downwelling vector irradiance as energy standard deviation of electromagnetic radiation (longwave) in the atmosphere by pyrgeometer |
N15NO3X1 | Enrichment standard deviation of nitrogen-15 in nitrate {15N in NO3- CAS 14390-96-6} {delta(15)N} in the water body [dissolved plus reactive particulate <GF/F phase] by filtration and Continuous-Flow Isotope Ratio Mass-Spectrometry |
ND143SD1 | Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) standard deviation of neodymium-143 {143Nd CAS 14336-83-5} {epsilon(143)Nd} in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration |
NDCHAT09 | Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) standard deviation of neodymium-143 {143Nd CAS 14336-83-5} {epsilon Nd value} in the atmosphere [aerosol phase] by inductively-coupled plasma mass spectrometry |
PCSDECAL | Partial pressure standard deviation of carbon dioxide {CO2 CAS 124-38-9} {pCO2} in the experiment water sample by computation |
PCSDWCAL | Partial pressure standard deviation of carbon dioxide {CO2 CAS 124-38-9} {pCO2} in the water body by computation |
SD13CMTX | Enrichment standard deviation of carbon-13 in inorganic carbon {13C in inorganic_C CAS 14762-74-4} {delta(13)C} in the water body [dissolved plus reactive particulate phase] by acidification and mass spectrometry |
SD15MTP1 | Enrichment standard deviation of nitrogen-15 in total nitrogen {15N_in_total_N CAS 14390-96-6} {delta(15)N} in the water body [particulate >GF/F phase] by filtration, combustion and mass spectrometry |
SDCOCVZZ | Log ligand binding strength standard deviation of cobalt-complexing organic ligands {Co_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
SDD3HEXX | Enrichment standard deviation of helium-3 {3He CAS 14762-55-1} in the water body [dissolved plus reactive particulate phase] by mass spectrometry |