Conceptid (135) | Preflabel |
---|
PBPSUSSE | Concentration standard error of lead {Pb CAS 7439-92-1} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
PHEOSE01 | Concentration standard error of phaeophytin-a {pheophytin-a CAS 603-17-8} per unit volume of the water body [particulate >GF/F phase] by filtration, acetone extraction and fluorometry |
PHPSINSE | Concentration standard error of total phosphorus {total_P CAS 7723-14-0} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
PHPSUSSE | Concentration standard error of total phosphorus {total_P CAS 7723-14-0} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
PSETH228 | Activity standard error of thorium-228 {228Th CAS 14274-82-9} per unit volume of the water body [particulate 1-51um phase] by filtration |
SB10IGD2 | Activity standard error of lead-210 {210Pb CAS 14255-04-0} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] |
SB10IGD9 | Activity standard error of lead-210 {210Pb CAS 14255-04-0} per unit volume of the water body [dissolved plus reactive particulate <1um phase] by filtration, Mn absorption and isotope spiking and ingrowth |
SB10IGP2 | Activity standard error of lead-210 {210Pb CAS 14255-04-0} per unit volume of the water body [particulate >0.4/0.45um phase] |
SB10IGP8 | Activity standard error of lead-210 {210Pb CAS 14255-04-0} per unit volume of the water body [particulate >1um phase] |
SDLFCVE6 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
SDND237T | Activity standard error of neptunium-237 {237Np CAS 13994-20-2} per unit volume of the water body [dissolved plus reactive particulate phase] by inductively-coupled plasma mass spectrometry and concentration to activity conversion based on half life |
SE09GSD2 | Activity standard error of plutonium-239+plutonium-240 {239Pu+240Pu} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and gamma spectroscopy |
SE09GSTX | Activity standard error of plutonium-239+plutonium-240 {239Pu+240Pu} per unit volume of the water body [dissolved plus reactive particulate phase] by gamma spectroscopy |
SE234TH4 | Activity standard error of thorium-234 {234Th CAS 15065-10-8} per unit volume of the water body [particulate 1-51um phase] by filtration and beta spectroscopy |
SE234TH5 | Activity standard error of thorium-234 {234Th CAS 15065-10-8} per unit volume of the water body [particulate >51um phase] by filtration and beta spectroscopy |
SE37GSD2 | Activity standard error of caesium-137 {137Cs CAS 10045-97-3} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and gamma spectroscopy |
SE37GSD5 | Activity standard error of caesium-137 {137Cs CAS 10045-97-3} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and gamma spectroscopy |
SE37GSTX | Activity standard error of caesium-137 {137Cs CAS 10045-97-3} per unit volume of the water body [dissolved plus reactive particulate phase] by gamma spectroscopy |
SE38GSD2 | Activity standard error of plutonium-238 {238Pu CAS 13981-16-3} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and gamma spectroscopy |
SE38GSTX | Activity standard error of plutonium-238 {238Pu CAS 13981-16-3} per unit volume of the water body [dissolved plus reactive particulate phase] by gamma spectroscopy |
SE90GSD2 | Activity standard error of strontium-90 {90Sr CAS 10098-97-2} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and gamma spectroscopy |
SE90GSTX | Activity standard error of strontium-90 {90Sr CAS 10098-97-2} per unit volume of the water body [dissolved plus reactive particulate phase] by gamma spectroscopy |
SEAMHOTX | Concentration standard error of ammonium {NH4+ CAS 14798-03-9} per unit volume of the water body [dissolved plus reactive particulate phase] by hypobromate oxidation |
SECOUV09 | Concentration standard error of cobalt {Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate phase] by UV digestion and flow-injection chemiluminescence |
SENIMATX | Concentration standard error of nitrite {NO2- CAS 14797-65-0} per unit volume of the water body [dissolved plus reactive particulate phase] by manual colorimetric analysis |