Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (107)Preflabel
FESDICP2Concentration standard deviation of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
FEXXAAP2Concentration of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and atomic absorption spectroscopy
FEXXICP2Concentration of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
GAPICP01Concentration of gallium {Ga CAS 7440-55-3} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
GASDICP1Concentration standard deviation of gallium {Ga CAS 7440-55-3} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
MNPICP01Concentration of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
MNPSINSEConcentration standard error of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
MNPSUSSEConcentration standard error of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
MNSDICP1Concentration standard deviation of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
MNSDICP2Concentration standard deviation of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
MNXXAAP2Concentration of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and atomic absorption spectroscopy
MNXXICP2Concentration of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
MOPICP01Concentration of molybdenum {Mo CAS 7439-98-7} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
MOSDICP1Concentration standard deviation of molybdenum {Mo CAS 7439-98-7} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NDPSINSEConcentration standard error of neodymium {Nd CAS 7440-00-8} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NDPSUSSEConcentration standard error of neodymium {Nd CAS 7440-00-8} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NIPICP01Concentration of nickel {Ni CAS 7440-02-0} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NIPSINSEConcentration standard error of nickel {Ni CAS 7440-02-0} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NIPSUSSEConcentration standard error of nickel {Ni CAS 7440-02-0} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NISDICP1Concentration standard deviation of nickel {Ni CAS 7440-02-0} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NISDICP2Concentration standard deviation of nickel {Ni CAS 7440-02-0} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NIXXAAP2Concentration of nickel {Ni CAS 7440-02-0} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and atomic absorption spectroscopy
NIXXICP2Concentration of nickel {Ni CAS 7440-02-0} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
PBPICP01Concentration of lead {Pb CAS 7439-92-1} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
PBPSINSEConcentration standard error of lead {Pb CAS 7439-92-1} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry