Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (61)Preflabel
NDCHUR02Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) standard error of neodymium-143 {143Nd CAS 14336-83-5} {epsilon Nd value standard error} in the water body [dissolved plus reactive particulate <0.2um phase] by inductively-coupled plasma mass spectrometry
NDKGSEMSConcentration standard error of neodymium {Nd CAS 7440-00-8} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
NDPSINSEConcentration standard error of neodymium {Nd CAS 7440-00-8} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NDPSUSSEConcentration standard error of neodymium {Nd CAS 7440-00-8} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NIPSINSEConcentration standard error of nickel {Ni CAS 7440-02-0} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
NIPSUSSEConcentration standard error of nickel {Ni CAS 7440-02-0} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
PA02KGSDConcentration standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
PA04KGSDConcentration standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
PA23SDPAConcentration standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit volume of the water body [particulate 0.4/0.45-51um phase] by filtration and inductively-coupled plasma mass spectrometry
PBPSINSEConcentration standard error of lead {Pb CAS 7439-92-1} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
PBPSUSSEConcentration standard error of lead {Pb CAS 7439-92-1} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
PHPSINSEConcentration standard error of total phosphorus {total_P CAS 7723-14-0} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
PHPSUSSEConcentration standard error of total phosphorus {total_P CAS 7723-14-0} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry
SDND237TActivity standard error of neptunium-237 {237Np CAS 13994-20-2} per unit volume of the water body [dissolved plus reactive particulate phase] by inductively-coupled plasma mass spectrometry and concentration to activity conversion based on half life
SEPU239TActivity standard error of plutonium-239 {239Pu CAS 15117-48-3} per unit volume of the water body [dissolved plus reactive particulate phase] by inductively-coupled plasma mass spectrometry and concentration to activity conversion based on half life
SEPU240TActivity standard error of plutonium-240 {240Pu CAS 14119-33-6} per unit volume of the water body [dissolved plus reactive particulate phase] by inductively-coupled plasma mass spectrometry and concentration to activity conversion based on half life
SETH230KConcentration standard error of thorium-230 {230Th CAS 14269-63-7} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
T23002SDConcentration standard error of thorium-230 {230Th CAS 14269-63-7} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
T230TLSDConcentration standard error of thorium-230 {230Th CAS 14269-63-7} per unit mass of the water body [dissolved plus reactive particulate phase] by acidification and inductively-coupled plasma mass spectrometry
T23202SDConcentration standard error of thorium-232 {232Th} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
T23245SDConcentration standard error of thorium-232 {232Th} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
T232TLSDConcentration standard error of thorium-232 {232Th} per unit mass of the water body [dissolved plus reactive particulate phase] by acidification and inductively-coupled plasma mass spectrometry
TH230SDPConcentration standard error of thorium-230 {230Th CAS 14269-63-7} per unit volume of the water body [particulate 0.4/0.45-51um phase] by filtration and inductively-coupled plasma mass spectrometry
TH232SD7Concentration standard error of thorium-232 {232Th} per unit mass of the water body [particulate 0.8-51um phase] by filtration and inductively-coupled plasma mass spectrometry
TH232SD8Concentration standard error of thorium-232 {232Th} per unit mass of the water body [particulate >51um phase] by filtration and inductively-coupled plasma mass spectrometry