Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (38)Preflabel
ARURXX04Activity ratio standard deviation of uranium-238/uranium-236 {238U/236U} in the water body [dissolved plus reactive particulate <unknown phase]
D14CMIEREnrichment combined uncertainty of carbon-14 {14C CAS 14762-75-5} in the water body [dissolved plus reactive particulate phase]
D14CMIXXEnrichment of carbon-14 {14C CAS 14762-75-5} in the water body [dissolved plus reactive particulate phase]
IORTAMDPAtomic ratio of iodine-129/iodine-127 {129I/127I} in the water body [dissolved plus reactive particulate phase] by AgI precipitation and accelerator mass spectrometry
MXTX3H1HAtomic ratio of tritium/hydrogen {concentration of tritium} in the water body [dissolved plus reactive particulate phase]
MXTX3HERAtomic ratio combined uncertainty of tritium/hydrogen in the water body [dissolved plus reactive particulate phase]
PB67MSD2Atomic ratio of lead-206/lead-207 {206Pb/207Pb} in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and inductively-coupled plasma mass spectrometry
PB67MSP2Atomic ratio of lead-206/lead-207 {206Pb/207Pb} in the water body [particulate >0.4/0.45um phase] by filtration and inductively-coupled plasma mass spectrometry
R226228EActivity ratio standard error of radium-228/radium-226 {228Ra/226Ra} in the water body [dissolved plus reactive particulate phase]
RA226228Activity ratio of radium-228/radium-226 {228Ra/226Ra} in the water body [dissolved plus reactive particulate phase]
S3HHMXTXAtomic ratio standard error of tritium/hydrogen in the water body [dissolved plus reactive particulate phase]
SEIRAMDPAtomic ratio standard error of iodine-129/iodine-127 {129I/127I} in the water body [dissolved plus reactive particulate phase] by AgI precipitation and accelerator mass spectrometry
U236238UAtomic ratio uncertainty of uranium-236/uranium-238 {236U/238U} in the water body [dissolved plus reactive particulate phase]
U236U238Atomic ratio of uranium-236/uranium-238 {236U/238U} in the water body [dissolved plus reactive particulate phase]