Conceptid (21) | Preflabel |
---|
BB142RVL | Attenuation due to backscatter of electromagnetic radiation (700nm wavelength at 142 degree incidence) by the water body by in-situ optical backscatter measurement |
BPVSO412 | Volume scattering attributable to particles of electromagnetic radiation (412nm wavelength) {Beta(p)} in the water body by in-situ optical backscatter measurement |
BPVSO470 | Volume scattering attributable to particles of electromagnetic radiation (470nm wavelength) {Beta(p)} in the water body by in-situ optical backscatter measurement |
BPVSO532 | Volume scattering attributable to particles of electromagnetic radiation (532nm wavelength) {Beta(p)} in the water body by in-situ optical backscatter measurement |
BPVSO650 | Volume scattering attributable to particles of electromagnetic radiation (650nm wavelength) {Beta(p)} in the water body by in-situ optical backscatter measurement |
BPVSO700 | Volume scattering attributable to particles of electromagnetic radiation (700nm wavelength) {Beta(p)} in the water body by in-situ optical backscatter measurement |
BPVSO880 | Volume scattering attributable to particles of electromagnetic radiation (880nm wavelength) {Beta(p)} in the water body by in-situ optical backscatter measurement |
BVSFO412 | Volume scattering coefficient of electromagnetic radiation (412nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement |
BVSFO470 | Volume scattering coefficient of electromagnetic radiation (470nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement |
BVSFO532 | Volume scattering coefficient of electromagnetic radiation (532nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement |
BVSFO650 | Volume scattering coefficient of electromagnetic radiation (650nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement |
BVSFO700 | Volume scattering coefficient of electromagnetic radiation (700nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement |
BVSFO880 | Volume scattering coefficient of electromagnetic radiation (880nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement |
NVLTOBS1 | Raw signal (counts) of instrument output by in-situ optical backscatter measurement |
ROPBS470 | Raw signal (counts) of instrument output (470nm wavelength) by in-situ optical backscatter measurement |
ROPBS532 | Raw signal (counts) of instrument output (532nm wavelength) by in-situ optical backscatter measurement |
ROPBS650 | Raw signal (counts) of instrument output (650nm wavelength) by in-situ optical backscatter measurement |
ROPBS700 | Raw signal (counts) of instrument output (700nm wavelength) by in-situ optical backscatter measurement |
ROPBS880 | Raw signal (counts) of instrument output (880nm wavelength) by in-situ optical backscatter measurement |
TURBPR01 | Turbidity of water in the water body by in-situ optical backscatter measurement and laboratory calibration against formazin |
TUSDPR01 | Turbidity standard deviation of water in the water body by in-situ optical backscatter measurement and laboratory calibration against formazin |