Conceptid (94) | Preflabel |
---|
LGFECVD5 | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
LGFECVDN | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <10**6 Dalton phase] by filtration and cathodic stripping voltammetry |
LGFECVDX | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
LGZNCVDX | Concentration of zinc-complexing organic ligands {Zn_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
LOGCUCS5 | Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
LTM00330 | Log ligand binding strength of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
LTM00440 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
LTM00550 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
LTM00880 | Log ligand binding strength of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
LTM00990 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
LTM01010 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
LTM01313 | Log ligand binding strength of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
LTM01414 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
LTM01515 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
LTM01818 | Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
LTM01919 | Log ligand binding strength lower uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
LTM02020 | Log ligand binding strength upper uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
LTM02323 | Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
LTM02424 | Log ligand binding strength lower uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
LTM02525 | Log ligand binding strength upper uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
LTM02828 | Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
LTM02929 | Log ligand binding strength lower uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
LTM03030 | Log ligand binding strength upper uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
NIXXCVDX | Concentration of nickel {Ni CAS 7440-02-0} per unit volume of the water body [dissolved plus reactive particulate phase] by UV digestion and cathodic stripping voltammetry |
SDCOCVZZ | Log ligand binding strength standard deviation of cobalt-complexing organic ligands {Co_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |