Conceptid (28) | Preflabel |
---|
ASAMAP05 | Amplitude of acoustic signal returns from the water body by acoustic doppler current profiler (ADCP) vertical beam |
CFACZZ01 | Correlation factor of acoustic signal returns from the bed by altimeter |
CMAGZZ01 | Correlation magnitude of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 1 |
CMAGZZ02 | Correlation magnitude of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 2 |
CMAGZZ03 | Correlation magnitude of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 3 |
CMAGZZ04 | Correlation magnitude of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 4 |
CMAGZZ05 | Correlation magnitude of acoustic signal returns from the water body by acoustic doppler current profiler (ADCP) vertical beam |
CMAGZZ06 | Correlation magnitude mean of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) and averaging of all functional beams |
ENLVZZ01 | Energy level of acoustic signal returns from the bed by altimeter |
LRZUVP01 | Upward velocity of acoustic signal returns from the water body by acoustic doppler current profiler (ADCP) vertical beam |
PCGDAP00 | Acceptable proportion of acoustic signal returns {percent good} from the water body by moored acoustic doppler current profiler (ADCP) beam 1 |
PCGDAP01 | Acceptable proportion of acoustic signal returns {percent good} from the water body by acoustic doppler current profiler (ADCP) |
PCGDAP02 | Acceptable proportion of acoustic signal returns {percent good} from the water body by moored acoustic doppler current profiler (ADCP) beam 2 |
PCGDAP03 | Acceptable proportion of acoustic signal returns {percent good} from the water body by moored acoustic doppler current profiler (ADCP) beam 3 |
PCGDAP04 | Acceptable proportion of acoustic signal returns {percent good} from the water body by moored acoustic doppler current profiler (ADCP) beam 4 |
PCGDAP05 | Acceptable proportion of acoustic signal returns {percent good} from the water body by acoustic doppler current profiler (ADCP) vertical beam |
PCGDAP06 | Acceptable proportion of acoustic signal returns {percent good} from the water body by moored acoustic doppler current profiler (ADCP) |
PCGDSA01 | Acceptable proportion of acoustic signal returns {percent good} from the water body by shipborne acoustic doppler current profiler (ADCP) |
TNIHCE01 | Echo intensity of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 1 |
TNIHCE02 | Echo intensity of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 2 |
TNIHCE03 | Echo intensity of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 3 |
TNIHCE04 | Echo intensity of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 4 |
TNIHCE05 | Echo intensity of acoustic signal returns from the water body by acoustic doppler current profiler (ADCP) vertical beam |
TNIHSB01 | Echo intensity of acoustic signal returns from the water body by shipborne acoustic doppler current profiler (ADCP) beam 1 |