Conceptid (34) | Preflabel |
---|
COLGCVDX | Concentration of organic ligand-bound cobalt {ligand-complexed_Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
CTM00110 | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
CTM00220 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
CTM00660 | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
CTM00770 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
CTM01111 | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
CTM01212 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
CTM01616 | Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
CTM01717 | Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
CTM02121 | Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
CTM02222 | Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
CTM02626 | Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
CTM02727 | Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
FENHEMS1 | Concentration of ferrioxamine E {hydroxamate siderophore CAS 20008-20-2} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and high performance liquid chromatography - inductively coupled plasma mass spectrometry |
FENHESD1 | Concentration standard deviation of ferrioxamine E {hydroxamate siderophore CAS 20008-20-2} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and high performance liquid chromatography - inductively coupled plasma mass spectrometry |
FENHGMS1 | Concentration of ferrioxamine G per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and high performance liquid chromatography - inductively coupled plasma mass spectrometry |
FENHGSD1 | Concentration standard deviation of ferrioxamine G per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and high performance liquid chromatography - inductively coupled plasma mass spectrometry |
LGCOCVDX | Concentration of cobalt-complexing organic ligands {Co_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
LGCUCSL1 | Concentration of copper-complexing organic ligands (of the stronger dissolved copper-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
LGFECIL1 | Concentration 95 per cent confidence interval of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
LGFECIL2 | Concentration 95 per cent confidence interval of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
LGFECIL3 | Concentration 95 per cent confidence interval of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
LGFECSL1 | Concentration of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
LGFECSL2 | Concentration of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |