Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (20)Preflabel
IASEIIP1Uptake rate standard error of ammonium {NH4+ CAS 14798-03-9} per day per unit area of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, incubation at different light levels, filtration and mass spectrometry on residue and profile integration
INSEIIP1Uptake rate standard error of nitrate {NO3- CAS 14797-55-8} per day per unit area of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, incubation at different light levels, filtration and mass spectrometry on residue and profile integration
NAUEROP1Uptake rate standard error of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, filtration and mass spectrometry on residue
NCUEROP6Uptake rate standard error of carbon {C} per hour per unit volume of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, cascade filtration and counting residue and summation of size-fractionated values
NNUEROP1Uptake rate standard error of nitrate {NO3- CAS 14797-55-8} per hour per unit volume of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, filtration and mass spectrometry on residue
PCUEIIP4Uptake rate standard error of carbon {C} per day per unit volume of the water body [particulate >0.2um phase] by isotope-labelled tracer addition, incubation at unspecified light level, cascade filtration and counting residue and summation of size-fractionated values
PCUEIIP5Uptake rate standard error of carbon {C} {primary production standard error} per day per unit volume of the water body [particulate >0.2um phase] by isotope-labelled tracer addition, incubation at unspecified light level, filtration and counting residue
SCUEIIPFUptake rate standard error of carbon {C} {primary production standard error} per day per unit volume of the water body [particulate 0.2-2um phase] by isotope-labelled tracer addition, incubation at unspecified light level, cascade filtration and counting residue
SCUEIIPGUptake rate standard error of carbon {C} {primary production standard error} per day per unit volume of the water body [particulate 2-20um phase] by isotope-labelled tracer addition, incubation at unspecified light level, cascade filtration and counting residue
SCUEIIPQUptake rate standard error of carbon {C} {primary production standard error} per day per unit volume of the water body [particulate >20um phase] by isotope-labelled tracer addition, incubation at unspecified light level, filtration and counting residue
SECURAAAUptake rate standard error of carbon {C} {primary production standard error} per hour per unit volume of the water body [particulate >20um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, filtration and counting residue
SECURAABUptake rate standard error of carbon {C} {primary production standard error} per hour per unit volume of the water body [particulate 2-20um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, cascade filtration and counting residue
SECURAACUptake rate standard error of carbon {C} per hour per unit volume of the water body [particulate >2um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, cascade filtration and counting residue and summation of size-fractionated values
SECURAXXUptake rate standard error of carbon {C} {primary production standard error} per hour per unit volume of the water body [particulate 0.2-2um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, cascade filtration and counting residue
SECURAYYUptake rate standard error of carbon {C} {primary production standard error} per hour per unit volume of the water body [particulate >0.2um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, filtration and counting residue
SECURAZZUptake rate standard error of carbon {C} {primary production standard error} per hour per unit volume of the water body [particulate >2um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, filtration and counting residue
SECURP2CUptake rate standard error of carbon {C} per hour per unit volume of the water body [particulate >0.2um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, cascade filtration and counting residue and summation of size-fractionated values
SNCEROPAUptake rate standard error of carbon {C} {primary production standard error} per hour per unit volume of the water body [particulate >5um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, filtration and counting residue
SNCEROPCUptake rate standard error of carbon {C} {primary production standard error} per hour per unit volume of the water body [particulate 2-5um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, cascade filtration and counting residue
SNCEROPNUptake rate standard error of carbon {C} {primary production standard error} per hour per unit volume of the water body [particulate GF/F-2um phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, cascade filtration and counting residue