Conceptid (20) | Preflabel |
---|
FVFMFIR1 | Photochemical quantum efficiency {Fv/Fm} in the water body by fluorescence induction and relaxation (FIRe) fluorometer and calculation from Fm and Fo fluorescence yields from the dark chamber |
FVFMFIRX | Photochemical quantum efficiency {Fv/Fm} in the water body by fluorescence induction and relaxation (FIRe) fluorometer and calculation from blank-corrected Fm and Fo fluorescence yields from the dark chamber |
FVFMFR01 | Photochemical quantum efficiency {Fv/Fm or Phi} in the water body by in-situ fast repetition rate fluorometer (FRRF) and calculation from Fm and Fo fluorescence yields from the dark chamber |
FVFMFR02 | Photochemical quantum efficiency {Fv/Fm or Phi} in the water body by in-situ fast repetition rate fluorometer (FRRF) and calculation from Fm and Fo fluorescence yields from the light chamber |
FVFMFR03 | Photochemical quantum efficiency {Fv/Fm} in the water body by in-situ fast repetition rate fluorometer (FRRF) and calculation from blank-corrected Fm and Fo fluorescence yields from the light chamber |
FVFMFR04 | Photochemical quantum efficiency {Fv/Fm} in the water body by in-situ fast repetition rate fluorometer (FRRF) and calculation from blank-corrected Fm and Fo fluorescence yields from the dark chamber |
FVFMMI01 | Photochemical quantum efficiency {Fv/Fm} in the water body by bench fast repetition rate fluorometer (FRRF) and calculation from Fm and Fo fluorescence yields from the dark chamber |
FVFMMIBL | Photochemical quantum efficiency {Fv/Fm} in the water body by bench fast repetition rate fluorometer (FRRF) and calculation from blank-corrected Fm and Fo fluorescence yields from the dark chamber |
NF01FR01 | Photochemical quantum efficiency {Fv/Fm} in the water body by single turnover fast repetition rate (FRR) fluorometry |
NF01FR02 | Photochemical quantum efficiency standard deviation {Fv/Fm} in the water body by single turnover fast repetition rate (FRR) fluorometry |
NS01FR01 | Functional absorption cross-section {Sigma-PSII} in the water body by single turnover fast repetition rate (FRR) fluorometry |
NS01FR02 | Functional absorption cross-section standard deviation {Sigma-PSII} in the water body by single turnover fast repetition rate (FRR) fluorometry |
NT01FR01 | Rate of Qa reoxidation {1/TauQa} in the water body by single turnover fast repetition rate (FRR) fluorometry |
NT01FR02 | Rate of Qa reoxidation standard deviation {1/TauQa} in the water body by single turnover fast repetition rate (FRR) fluorometry |
SIGFRBL1 | Functional absorption cross-section {Sigma-PSII} in the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the light chamber |
SIGFRBL2 | Functional absorption cross-section {Sigma-PSII} in the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the dark chamber |
SIGMFR01 | Functional absorption cross-section {Sigma-PSII} in the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber |
SIGMFR02 | Functional absorption cross-section {Sigma-PSII} in the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the raw data from the light chamber |
SIGPSII1 | Functional absorption cross-section {Sigma-PSII} in the water body by bench fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber |
TAUQAI01 | Rate of Qa reoxidation {1/TauQa} in the water body by bench fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber |