Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (20)Preflabel
FESECLDXConcentration standard error of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [dissolved plus reactive particulate phase] by flow-injection chemiluminescence
IIDECVSEConcentration standard error of iodide {I- CAS 20461-54-5} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry
SDND237TActivity standard error of neptunium-237 {237Np CAS 13994-20-2} per unit volume of the water body [dissolved plus reactive particulate phase] by inductively-coupled plasma mass spectrometry and concentration to activity conversion based on half life
SE09GSTXActivity standard error of plutonium-239+plutonium-240 {239Pu+240Pu} per unit volume of the water body [dissolved plus reactive particulate phase] by gamma spectroscopy
SE37GSTXActivity standard error of caesium-137 {137Cs CAS 10045-97-3} per unit volume of the water body [dissolved plus reactive particulate phase] by gamma spectroscopy
SE38GSTXActivity standard error of plutonium-238 {238Pu CAS 13981-16-3} per unit volume of the water body [dissolved plus reactive particulate phase] by gamma spectroscopy
SE90GSTXActivity standard error of strontium-90 {90Sr CAS 10098-97-2} per unit volume of the water body [dissolved plus reactive particulate phase] by gamma spectroscopy
SEAMHOTXConcentration standard error of ammonium {NH4+ CAS 14798-03-9} per unit volume of the water body [dissolved plus reactive particulate phase] by hypobromate oxidation
SECOUV09Concentration standard error of cobalt {Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate phase] by UV digestion and flow-injection chemiluminescence
SENIMATXConcentration standard error of nitrite {NO2- CAS 14797-65-0} per unit volume of the water body [dissolved plus reactive particulate phase] by manual colorimetric analysis
SENZMATXConcentration standard error of nitrate+nitrite {NO3+NO2} per unit volume of the water body [dissolved plus reactive particulate phase] by manual colorimetric analysis
SEOCCOTXConcentration standard error of organic carbon {organic_C CAS 7440-44-0} {DOC} per unit volume of the water body [dissolved plus reactive particulate phase] by high temperature Pt catalytic oxidation
SEPU239TActivity standard error of plutonium-239 {239Pu CAS 15117-48-3} per unit volume of the water body [dissolved plus reactive particulate phase] by inductively-coupled plasma mass spectrometry and concentration to activity conversion based on half life
SEPU240TActivity standard error of plutonium-240 {240Pu CAS 14119-33-6} per unit volume of the water body [dissolved plus reactive particulate phase] by inductively-coupled plasma mass spectrometry and concentration to activity conversion based on half life
SERA223UActivity standard error of radium-223 {223Ra} per unit volume of the water body [dissolved plus reactive particulate phase]
SERA224UActivity standard error of radium-224 {224Ra CAS 13233-32-4} per unit volume of the water body [dissolved plus reactive particulate phase]
SERA226UActivity standard error of radium-226 {226Ra CAS 13982-63-3} per unit volume of the water body [dissolved plus reactive particulate phase]
SERA228UActivity standard error of radium-228 {228Ra CAS 15262-20-1} per unit volume of the water body [dissolved plus reactive particulate phase]
SHECMXXXConcentration standard error of helium {He CAS 7440-59-7} per unit volume of the water body [dissolved plus reactive particulate phase] by mass spectrometry
SNECMXXXConcentration standard error of neon {Ne CAS 7440-01-9} per unit volume of the water body [dissolved plus reactive particulate phase] by mass spectrometry