Conceptid (13) | Preflabel |
---|
DFFELXX1 | Concentration of iron-complexing organic ligands (excess, non-complexed) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
FELGCVDX | Concentration of iron (ligand complexed) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
LGCUCSV5 | Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
LGCUSDA5 | Concentration standard deviation of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
LGFECVDX | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
LGFECVLL | Concentration of iron-complexing organic ligands (iron-complexing, lower limit calculated from filtered (<0.2um) Fe) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
LGFECVUL | Concentration of iron-complexing organic ligands (iron-complexing, upper limit calculated from unfiltered iron concentration) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
LGZNCVDX | Concentration of zinc-complexing organic ligands {Zn_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
SDLFCVDX | Concentration standard deviation of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
SDLFCVLL | Concentration standard deviation of iron-complexing organic ligands (iron-complexing, lower limit calculated from filtered (<0.2um) Fe) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
SDLFCVUL | Concentration standard deviation of iron-complexing organic ligands (iron-complexing, upper limit calculated from unfiltered iron concentration) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
SDLZCVDX | Concentration standard deviation of zinc-complexing organic ligands {Zn_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |
ZNLGCVDX | Concentration of organic ligand-bound zinc {ligand-complexed_Zn CAS 7440-66-6} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry |