Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (17)Preflabel
DGTLALSDConcentration standard deviation of aluminium {Al CAS 7429-90-5} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLALXXConcentration of aluminium {Al CAS 7429-90-5} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLCDSDConcentration standard deviation of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLCDXXConcentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLCOSDConcentration standard deviation of cobalt {Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLCOXXConcentration of cobalt {Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLCUSDConcentration standard deviation of copper {Cu CAS 7440-50-8} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLCUXXConcentration of copper {Cu CAS 7440-50-8} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLFESDConcentration standard deviation of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLFEXXConcentration of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLMNSDConcentration standard deviation of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLMNXXConcentration of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLNISDConcentration standard deviation of nickel {Ni CAS 7440-02-0} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLNIXXConcentration of nickel {Ni CAS 7440-02-0} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLPBSDConcentration standard deviation of lead {Pb CAS 7439-92-1} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
DGTLPBXXConcentration of lead {Pb CAS 7439-92-1} per unit volume of the water body [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and inductively-coupled plasma mass spectrometry
FEXXASPWConcentration of total iron {total_Fe CAS 7439-89-6} per unit volume of the sediment pore water [dissolved plus reactive particulate phase] by diffusive gel thin-film (DGT) sampling, extraction into HNO3 and graphite furnace atomic absorption spectroscopy