Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (78)Preflabel
ARTH02SDActivity ratio standard error of thorium-232/thorium-230 {232Th/230Th} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
ARTHTTSDActivity ratio standard error of thorium-232/thorium-230 {232Th/230Th} in the water body [dissolved plus reactive particulate phase] by acidification and inductively-coupled plasma mass spectrometry
DSETH228Activity standard error of thorium-228 {228Th CAS 14274-82-9} per unit volume of the water body [dissolved plus reactive particulate <1um phase] by filtration
ET34GPD2Activity standard error of thorium-234 {234Th CAS 15065-10-8} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, plating and gamma spectroscopy
ET34GSP2Activity standard error of thorium-234 {234Th CAS 15065-10-8} per unit volume of the water body [particulate >0.4/0.45um phase] by filtration and gamma spectroscopy
ET34SPD2Activity standard error of thorium-234 {234Th CAS 15065-10-8} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and alpha plus beta spectroscopy
ET34SPD9Activity standard error of thorium-234 {234Th CAS 15065-10-8} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and alpha plus beta spectroscopy
ET34SPP2Activity standard error of thorium-234 {234Th CAS 15065-10-8} per unit volume of the water body [particulate >0.4/0.45um phase] by filtration and alpha plus beta spectroscopy
ET34SPP9Activity standard error of thorium-234 {234Th CAS 15065-10-8} per unit volume of the water body [particulate >0.2um phase] by filtration, plating and alpha spectroscopy
P210STERActivity standard error of lead-210 {210Pb CAS 14255-04-0} per unit dry weight of suspended particulate material by sediment trapping, digestion, purification, plating and alpha spectroscopy
PA02KGSDConcentration standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
PA04KGSDConcentration standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry
PA231ER4Activity standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification
PA231ER5Activity standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit volume of the water body [particulate 0.8-51um phase] by filtration
PA231ER6Activity standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit volume of the water body [particulate >51um phase] by filtration
PA231ER8Activity standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit volume of the water body [particulate >0.8um phase] by filtration
PA231SE4Activity standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and corrected for the detrital contribution
PA231SE8Activity standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit volume of the water body [particulate >0.8um phase] by filtration and corrected for the detrital contribution
PA23SDPAConcentration standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit volume of the water body [particulate 0.4/0.45-51um phase] by filtration and inductively-coupled plasma mass spectrometry
PAKG1ER5Activity standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit mass of the water body [particulate 0.8-51um phase] by filtration
PAKG1ER6Activity standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit mass of the water body [particulate >51um phase] by filtration
PSETH228Activity standard error of thorium-228 {228Th CAS 14274-82-9} per unit volume of the water body [particulate 1-51um phase] by filtration
R226228EActivity ratio standard error of radium-228/radium-226 {228Ra/226Ra} in the water body [dissolved plus reactive particulate phase]
S3HHMXTXAtomic ratio standard error of tritium/hydrogen in the water body [dissolved plus reactive particulate phase]