Conceptid (3127) | Preflabel |
---|
TA569B26 | Proportion (in species count) of Calanus finmarchicus (ITIS: 85272: WoRMS 104464) [Stage: copepodites C2] in the water body by mitochondrial 16s rDNA restriction fragment length polymorphism (RFLP) signature identification |
TA615893 | Proportion (in species count) of Calanus glacialis (ITIS: 85267: WoRMS 104465) [Stage: nauplii N4-N6] in the water body by mitochondrial 16s rDNA restriction fragment length polymorphism (RFLP) signature identification |
TAUESD01 | Rate of Qa reoxidation standard deviation {1/TauQa} in the experiment water sample by bench fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber |
TAUEXI01 | Rate of Qa reoxidation {1/TauQa} in the experiment water sample by bench fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber |
TAUQAI01 | Rate of Qa reoxidation {1/TauQa} in the water body by bench fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber |
TDSSFT01 | Log10 temperature dissipation rate in the water body by turbulence profiler fast temperature sensor |
THRTAPXT | Activity ratio of thorium-230/thorium-232 {230Th/232Th} in the sediment by digestion, purification, plating and alpha spectroscopy |
THSCTP01 | Thorpe Scale in the water body by turbulence profiler precision CTD |
TINTTFBL | Turbulence intensity in the water body by thermistor flow meter |
TLRDZZ01 | Downwelling vector irradiance as energy of electromagnetic radiation (longwave + shortwave) {Total radiation} in the atmosphere |
TRTM2WAY | Two-way travel time of sound in the water body by echo sounder |
TRTM2WPR | Two-way travel time of sound in the water body by echo sounder and standardised to a reference pressure level using concurrent CTD profile data |
TURBAQ01 | Turbidity of water in the water body by Aquatracka nephelometer and laboratory calibration against formazin |
TURBAQ02 | Turbidity of water in the water body by nephelometry using an infrared light source and laboratory calibration against formazin |
TURBMEXX | Turbidity of water in the water body by programmable medium-spectral resolution imaging spectrometer (MERIS) |
TURBMOXX | Turbidity of water in the water body by Moderate Resolution Imaging Spectroradiometer (MODIS) |
TURBPR01 | Turbidity of water in the water body by in-situ optical backscatter measurement and laboratory calibration against formazin |
TURBPR02 | Turbidity of water in the water body by in-situ optical backscatter measurement (second sensor) and laboratory calibration against formazin |
TURBPR12 | Turbidity standard deviation of water in the water body by in-situ optical backscatter measurement (second sensor) and laboratory calibration against formazin |
TURBSC01 | Turbidity of water in the water body by SCUFA turbidity meter and laboratory calibration against formazin |
TURBSP01 | Turbidity of water in the water body by SeaPoint turbidity meter and laboratory calibration against formazin |
TURBSP02 | Turbidity of water in the water body by SeaPoint turbidity meter (second sensor) and laboratory calibration against formazin |
TURBSS01 | Turbidity of water in the water body by SeaTech light backscatter nephelometer (LBSS) and laboratory calibration against formazin |
TURBTNTX | Turbidity of water in the water body by through-flow nephelometer |