Conceptid (16) | Preflabel |
---|
CCA02044 | Concentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate 0.2-20um phase] by filtration, acid digestion and inductively-coupled plasma mass spectrometry |
CCA11005 | Concentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >0.4/0.45um phase] by filtration, acid digestion and inductively-coupled plasma mass spectrometry |
CCA11006 | Concentration standard deviation of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >0.4/0.45um phase] by filtration, acid digestion and inductively-coupled plasma mass spectrometry |
CCA20044 | Concentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >20um phase] by filtration, acid digestion and inductively-coupled plasma mass spectrometry |
CCA77028 | Concentration combined uncertainty of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >0.4/0.45um phase] by filtration, acid digestion and inductively-coupled plasma mass spectrometry |
CCA87044 | Concentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >0.2um phase] by filtration, acid digestion and inductively-coupled plasma mass spectrometry |
CCA87045 | Concentration standard deviation of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >0.2um phase] by filtration, acid digestion and inductively-coupled plasma mass spectrometry |
CDCNICP2 | Concentration of cadmium {Cd CAS 7440-43-9} per unit dry weight of suspended particulate material >0.4/0.45um by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
CDPICP01 | Concentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
CDPSINSE | Concentration standard error of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
CDPSUSSE | Concentration standard error of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate 0.8-51um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
CDSDICP1 | Concentration standard deviation of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >1um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
CDSDICP2 | Concentration standard deviation of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
CDXXICP2 | Concentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [particulate >0.4/0.45um phase] by acid leaching of filter residue and inductively-coupled plasma mass spectrometry |
MSPMM017 | Concentration of cadmium {Cd CAS 7440-43-9} per unit dry weight of suspended particulate material by inductively-coupled plasma mass spectrometry |
MSPMM025 | Concentration of cadmium {Cd CAS 7440-43-9} per unit dry weight of suspended particulate material by inductively-coupled plasma mass spectrometry and normalisation to organic carbon and lutum content (RIKZ 'standard sediment') |