Conceptid (13) | Preflabel |
---|
ALSELGD5 | Concentration standard error of aluminium {Al CAS 7429-90-5} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and lumogallion fluorescence |
CTM00220 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
CTM00770 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
CTM01212 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
CTM01717 | Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry |
CTM02222 | Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry |
CTM02727 | Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry |
DFEFICSE | Concentration standard error of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and flow-injection chemiluminescence |
NDSE02MS | Concentration standard error of neodymium {Nd CAS 7440-00-8} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry |
PA02KGSD | Concentration standard error of protactinium-231 {231Pa CAS 14331-85-2} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry |
SDLFCVE6 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
T23002SD | Concentration standard error of thorium-230 {230Th CAS 14269-63-7} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry |
T23202SD | Concentration standard error of thorium-232 {232Th} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry |